Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Y to use 4 to 20ma instead of 0-10v

Answer Posted / ecxlsync

current signal is used because as explained
it will not change even the loop resistance is changed
due to transmission lines resistance. it is stated in the KCL that current entering in the circuit will be equal to the
current leaving no matter if the circuit resistance is changed.

Voltage signal is greatly affected by the circuit resistance.
long distance transmission has large wire resistance that
will cause large voltage drop.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2174


How u will setup SPI(2007) on Citrix Server (Thin Client Mode)? Plz Justify?

2022


Where is wet leg is used?

1061


Draw a great bridge circuit.

2016


1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.

2421


what is span value and zero ? and how set ?

1572


Explain the working principle of lvdt?

1197


which type of filter gives the constant phase characteristics?

1926


wich is coming the first HAZOP OR SIL

2762


How many interlocks at turbine? Plz explain briefly

1957


I am having a Phoenix digital to modbus converter. The o/p of the same is connected to flow computer FB407. But the digital signals are updated only after one minute in the flow computer. what may be the cause of delay in communication? Flow computer is having a scanning period of less than 1 sec.

1903


please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?

8669


my data card only does run in my mobile so how can change it that it run other mobile & computer and i can stor data in my data card

2278


what is installation and commissioning of (fat & sat) of power plant dcs ? this question keeps in desirable conditions of one company .

4850


In which principles tx ,pressure gauge,Temp gauge,control valve works?

1821