what is difference between KW,KVA,KVAR? also give me the
formula for all the three...
Answer Posted / shiva prasad
P= POWER
P= V X I X COS@ IN AC
KW = P X 1000
KW= KILO WATT
KVA= IT IS NOTHING BUT KW
KVAR= V X I X SIN@ IN AC
KW= KVA X PF
| Is This Answer Correct ? | 15 Yes | 7 No |
Post New Answer View All Answers
Can we indroduce the principle of single phase induction mator to Transformer? i.e. by Producing rotating flux in the transformer.
is oil viscosity affect on motor current?
What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)
We are planning to synchronized DG's with our captive plant in the event of black start of plant, but before sync we checked voltage of DG with our plant voltage and it varies from 5 V to 450 V. So in this condition how we can sync DG with plant ?
what is the ms flat constant for calculating earth mat design calculation?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
how to calculate the tarriff for an industry whose kva demand is 10 mva
For a 6.6kV Motor it is recommended to do megger test with 500 V d.c and not more than 5kV d.c but the Hi voltage withstand test should be performed by 12kV AC. Why the dc voltage test should be limited but AC voltage withstand test could be with such a high voltage?
can anyone give an idea about dia calculation in cold rolling mill
any application of back emf
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
How the capacitance og capacitor volatage transformer is decided?
What the formula for calculating no.of earthings & size of earth strip for 100mX90m shop.
how net resistance islow in star connection and viseversa in delta connection...? if anybody could explain in detail it wud be helpful.
WHAT IS DOL STARTER? HOW IT WORK? GIVE ITS CONTROL AND POWER DIAGRAM .