Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is OLTC in a transformer, specify its fuction.

Answer Posted / hin sothea(ctl)

OLTC On Load Tap Changer in Tr. Is mean that the changing
Tap of Transformer is according to the changing of loads
at low voltage side. Any way chang Tap mean chang the turn
winding of Primary side of Tr.
Eg: VL=VHx(NL/NH)
V=P/I

If current at lower side is increased, the voltage at lower
side will be decreased and also for the voltage at higher
side.To make the voltage at lower side stable, the turn
winding at higher side must be higher than it befor. When
the turn is chang it is mean the Tap is chang.

By Ohm Law:

P : Stable
I :&#8594;&#8734;
V :&#8594;0
VL :constant,Low side Voltage(We need it be constang)
VH :constant,High side Voltage
NL :constant,Low side turn winding
NH :High side turn winding

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?

2946


why use phase displacement in transformer.and effect of phase displacement on transformer

2913


how indusrial diesel generator work

1959


TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?

1992


How RTCC panel is working and give single line diagram for RTCC with transformer?

3148


What is line resistance of cable & how it can be measured ?

1592


how you will decide the distance between the power transformer and its fencing

2010


Efficient electrical earthing in hard rock area

1628


Why do we pefer VCB over OCB?What are the advantages of VCB over OCB?

2676


what is the difference between interconnection and intraconnections in the circuit diagrams

8467


can you any one give exact mathematical relation between AC current and DC current?

2056


how to calculte capacitor range for single phase induction motors??pls tel

2170


Write the force balance equation of ideal spring element.

1307


i have interview in Pepsi company what type of question will ask please send the question and answeer

3522