Nilkant's answer with regard to transformer size is wrong.
For a given KVA rating of a transformer lower voltage would
require larger conductor cross section (current being
inversely proportional to voltage for a given power).
Therefore, larger conductor size will result in larger size
of transformer. As for the main question, I THINK Americans
use 110 Volts (instead of 230V)as rated voltage for end
users because lower voltage means higher safety factor for
consumers. Well it comes with a price! Their system will be
more expensive since all the wires of their home appliances
and distribution conductors will be larger in size. MAY BE
they are rich and can afford it!!!
Is This Answer Correct ? | 2 Yes | 4 No |
Post New Answer View All Answers
how to carried out tan delta test in 11 KV alternator ?
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
what is different between relay and plc?
Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?
what is induction furnance? how many phase supply given io its coil for 15 or 20 ton furnance?
Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit
I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.
How many kinds of E.L.C.B and how to work E.L.C.B
What will be the voltage regulation of a full load and 0.80 power factor lagging load transformer when a two winding single phase transformer has a voltage regulation of 4.5% at full load and unity power factor?
What is superposition theorem?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
IF I KNOW THE AREA OF CROSS SECTION OFTHE WIRE , WATTAGE OF THE LOAD ,VOLTAGE SUPPLY WHAT IM GIVING TO THE LOAD AND ALSO POWER FACTOR OF LOAD ....... SO GIVE ME FOR WHAT AMOUNT OF CURRENT I SHOULD USE WHICH TYPE OF CABLE?
reason of diode failure in alternator
WE ARE PLACE A NEW 75 KW MOTOR FOR JPF.IT IS CONNECTED IN M.C.C. WHEN WE ARE STARTING M.C.C.INCOMER IS TRIPPED.THEN WE ARE CONNECTED IN P.C.C WITH A MM30 RELAY PROTECTION THEN WE ARE STARTED MOTOR WILL RUN SMOOTHLY.
Haw to check conductivity of budbar