Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why the discharge pressure of ID fan showing negative at fan
running condition.(boiler operating condition.)

Answer Posted / naseer jarral

bcz this fan is inducing draft fan this is suctioning the
draft

Is This Answer Correct ?    4 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the process to make control schematic ?

2247


What is sensitivity in vibration probes..?

1644


What is exact difference between the panel earthing and system earthing in DCS system. What is the value of resistence.

2665


How to Calibrate Flow Switch in field

1256


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1663


Why even multiple power supplu r used in instrumentation system?

4985


Hi, Is there any smart plant instrumentation design training institute in Bangalore?

1672


Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.

2011


where proximity sensor installed on tank in loading arm application

1958


What happen if I install my pressure transmitter below the elevation of pipe in natural gas service?

1198


Somebody tell me in what way i need to prepare for csio pgrpe(adv instrum eng)interview?what all the quest can i expect?

2587


䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ

1954


Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

2500


basic connection and principle of axial shift sensor n differential sensors in tubine describes n draw......

2371


what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?

1977