Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the maintain in ACB,VCB,MCB,MCCB breakers?

Answer Posted / sajin rajan

VCB - VACCUM CIRCUIT BREAKER
ACB - AIR CIRCUIT BREAKER
MCCB - MOULDED CASE CIRCUIT BREAKER
MCB-MINIATURE CIRCUIT BREAKER

VCB IS NORMAY USED IN THE UPSTREAM SIDE i.e.HIGH VOLTAGE
SIDE FOR HIGH CURRENT,THE INSULATING MEDIUM OF THE
SWITCHING CONTACTS IS VACCUM.

ACB IS USED AT THE LOW VOLTAGE SIDE,INSULATING MEDIUM IS
AIR.


MCCB & MCB ARE USED IN THE DISTRIBUTION SIDE

Is This Answer Correct ?    9 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WHAT IS ELECTRICAL MAINTAINTENCE ?

2096


what are the specifications we must look at to select a relay for any capacity motor?

2042


what is mean by descripiency relay? & wht is its ansi code?

3170


How will polarity test of Dy5 Transformer ?

2271


Why 11kv to be generated in generation station

1673


why do we have spikes enough to burn electronic boards, when generators are not grounded

1815


Explain Continuous and Discrete signals?

1746


What is an alternator impedance value?

2860


After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.

2356


Usually in the L & T make MCC feeders' power circuit,we have BMR after the MAIN CONTACTOR.,can we interchange their position, keeping the control logic same???

2108


what is the Connected Load (kW) or Contract Demand (kVA)of mahindra nasik plant??

9495


explain working principle of earth leakage relay

3710


What is meant by cold loop test in instrument

2619


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2453


What do you mean by Stimulastion Test in Diesel Genarator / Why & when it's conducted ?

1654