sir,
how to select the cable size, what is the parameters use
ang what is the formulas use for this cable size
calculations. please tell me.

Answer Posted / raul

cable size depends upon THE MOST ECONOMICAL CONDUCTOR SIZE
concept in which the size depends upon the max. dielectric
stress on the conductor..........i.e. g(max.)= 2V/dlogD/d,
where V=voltage, x= distance from the conductor centre,
D=sheath diameter, d=conductor diameter........by
differentiating above relation n equating to zero......we
get logD/d=1 i.e. d=D/2.718...........

Is This Answer Correct ?    2 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.

1629


what is the effect of connecting three phase supply lines to three phase auto transformer output terminals through a fuse of 10Amp and a circuit breaker (MCB). Is this connection permanently destroy the transformer?

1465


Define resonant peak?

650


why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

1524


in indoor type circuit breakers why only the corner breaker trips specially during cold season. What is the reason.

1437






Why the power factor improvement is so important in industrial loads

1402


how can decide the current rating of oltc

1855


How it can worked plc based electrical system And which type of software using.

1666


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2258


DESCRIBE THE CONSTRUCTION ANDOPERATION OF BELT CONVEYORS AND SCR CONVEYORS , DRAW NEAT SKETCHES

1621


Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

1184


if the armature current in a dc generator is ac ( sinusoidal ) why doesnt the sjhape af armature mmf a sinusoidal (ni) ? armature mmf in case of a dc machine is triangular.

1502


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.

1472


Plz tell me how we can find that particular company has vacancy or not

1671


What should be the voltage between Neutral and Ground in secondary side of the step down transformer (230 V to 110 V) with no load condition?

1606