Answer Posted / binod bhanj
The most notable difference between a thermocouple and an RTD is the principle of operation and manufacturing. A thermocouple is made of two dissimilar metals joined so that a potential difference generated between the points of contact is a measure of the temperature. An RTD, operates on the principle that electrical resistance of certain metals changes in a predictable way depending on the rise or fall in temperature. The two measurement tools each have their own advantages and disadvantages.
Advantages of the thermocouple include a wide range from -300°F to 2300°F, fast response time (under a second in some cases), low initial cost and durability. Overall, thermocouples are able to withstand rugged applications. Disadvantages for thermocouples are their wide accuracy range, especially at elevated temperatures, difficult to recalibrate (seeing as though they are dependant upon the environment) and, finally, installation can be expensive if long lengths of thermocouple wire are needed.
On the flip side, advantages for RTDs include stable output over a long period of time, ease of recalibration, and accurate readings over narrow temperature spans. Disadvantages, when compared to the thermocouples, are: smaller overall temperature range ( -330°F to 930°F), higher initial cost and they are more fragile in rugged, industrial environments.
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
What is the difference between voltages or potential difference? And what are they?
what is acceptable leakage current for 33kv cable while doing high voltage test for cable? how to calaulate the leakage current for 33kv or any rated cable?
How could a garment factory benefit from renewable energy
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
Convert a star connected network into a delta connected network.
If the feeder rating is 7.5 kw or 10 HP star-delta feeder, MCCB is taken as 63 a, contactors-32 a, how much will be the OLR rating or which range OLR should be considered when we concern about type-2 coordination?
when we gave dc supply to 220v dc motor its rpm is 1200. then we gave 180v. how many rpm of its motor. gave answer with calculation at my ID.... ravizak@ymail.com
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
I have doubt that the supply HZ (very low or high than rated ) may affect the power factor. is it true. ?
what is sevice settings for mccb?How can be it setted?
Why PT voltages are measured with respect to ground? What do u mean by voltage or current polarized.
Mention what are the different colors on wires indicates?
3phase cable calculation formula by motor load
Give two basic speed control scheme of dc shunt motor?
I Want randstand placement papers