What is mean CT Saturation? How to calculate?
Answer Posted / lokesh devpura
Ans 6 and 9 are combinely correct. Actually if we want to
check CT saturation that means ouput current must be
correct according to its rating.
And output current is nothing but a voltage across its
secondary which is calculated as its current(like 1V=10A)
i.e. if 1 V output vltg across secondary you find that
means instrument will read 10A current.
So if CT gets saturated then it will read more than 1V and
correspondingly we find false output current.
Is This Answer Correct ? | 5 Yes | 13 No |
Post New Answer View All Answers
harmonics filter
What is the transfer function?
Do any one know exacatly when the results for NHPC held on 8th march 09 for engineering trainees will be released ?. if so please post it, i'm eager to know it.
WHY THE RATINGS OF THE TRANSFORMER IS 33KV WHY NOT OTHER???
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
What is the formula to calculate distribution transformer De-rating on iron losses basis
tell me some type of questions throught which i can prepare for exam and do my best
What is the tipical Online UPS input voltage for 20 KVA load ( 3 Phase or 1 Phase )? Why ? Explain it...?
(In MEP services) HVAC in AC Plant room what else can we provide if the chiller is not considered?
why core is useful for a transformer ?and also in its operation ?
What is the equivalent circuit of a transformer and its vector diagram?
HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER
I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.
How to decide DO set rating of Transformer?
What should be current in the Primary and secondary side of 1000KVA (11KV Supply)Transformer.?