What is use of condensate pot
Answer Posted / mr. rao
yes...., i aggrey with above answer, as well as steam
pressure flxevations also reducess.it meeans indirect
pressure will presented on diaframe, so transmitter out put
allso good.simple with help of condensate pot reducess
flexvationsas well as temperature effects up to serten
levels.
| Is This Answer Correct ? | 10 Yes | 4 No |
Post New Answer View All Answers
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
Any body have know try work calculation ???
Explain why plc require in analog input 4-20amp & 0-10 volt?
How to convert mmWc(mili meter water colam) to tph(ton per hour)?
What is the minimum rating availalbe for weld neck orifice in market?
What is the use of temprature compensation?
What are de-saturators?
what is RTV function in in process control?
how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???
why we are not using the turbine flow meter in the steam service?
what effects a surging can produce in the compressor
Explain signal isolator
How to calculate mmwc values into tonnes?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
How to check vortex flow meter is in good condition while we do not having calibration setup?