Answer Posted / s mirza
IP Enclosures
At Nema Enclosures, we strictly adhere to the International
Electrotechnical Commission standardized international (or
Ingress) Protection Code, which defines an enclosure's
rating. The IP Code reflects the degree of protection
as "IP" followed by two numbers. The first digit ranges
from 0 to 6, reflecting in degrees the level of protection
against particles, and protection to others from enclosed
hazards. The second digit ranges from 0 to 8 and indicates
the extent of protection against water. Because our
enclosures stringently observe these guidelines, you can
expect superior enclosures that are available in a number
of materials and types, and can be enhanced by our value
added services.
IP54 Enclosures' Characteristics:
• Protection from dirt, dust, oil, and other non-
corrosive material
• Protection from contact with enclosed equipment
• Protection from splashing water
• Available in aluminum, carbon steel, and stainless
steel
• Available in wall-mounted, free standing, troughs,
and JIC box
• Engraving, silk-screening, or anodizing services
available
Custom with cutouts, insulation, hinges, latches or locks
IP55 Enclosures' Characteristics:
• Protection from dirt, dust, oil, and other non-
corrosive material
• Complete protection from contact with enclosed
equipment
• Protection from water, up to water projected by a
nozzle against enclosure from any direction
• Available in aluminum, carbon steel, and stainless
steel
• Available in wall-mounted, free standing, trough,
and JIC box
• Engraving, silk-screening, or anodizing services
available
• Custom with cutouts, insulation, hinges, latches,
or locks
•
IP65 Enclosures' Characteristics:
• Complete protection from dust, oil, and other non-
corrosive material
• Complete protection from contact with enclosed
equipment
• Protection from water, up to water projected by a
nozzle against enclosure from any direction
• Silk-screening, anodizing, or engraving services
available
• Custom with cutouts, insulation, hinges, latches or
locks
IP66 Enclosures characteristics:
• Complete protection from dust, oil, and other non-
corrosive material
• Complete protection from contact with enclosed
equipment
• Protection from water, even from powerful jets of
water
• Equivalent to NEMA rated 4 and 4X enclosures
• Engraving, silk-screening, and anodizing services
available
• Custom with cutouts, insulation, hinges, latches or
locks
| Is This Answer Correct ? | 15 Yes | 2 No |
Post New Answer View All Answers
what is vtg limit of earth and neutral at transformer side?
is oil viscosity affect on motor current?
i have a 4 Mva transformer 34.5 kv / 480-277 v and i used 2 parallel 3200 amp bus duct for the secondary feeder using 3 ply of bus bar ( 3/8" x 5" ) as a common where the flexible link terminated and 6300 amps breaker for the main, the lower bus duct reaches 70 degrees and the upper bus duct reaches 55 degrees when i used thermal scanner. why the temperature is not balance when the load reaches 3600 amps.
how to calculate the distance relay faulty zone?pls explain?
What are the advantages of a three-phase system over a single-phase system?
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
What is Annunciation?
what are the range of memory address in plc for L&T lx7 4A
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
What is a differential amplifier? Also, explain cmrr.
why occ characteristics curve in not tracing back when we are bringing back the rhoestat?
how to ctrl motor by use of ac or dc drive.plz explain evdintly
what is the defination of Cable database? What are the points are considered while preparing cable database? Is there any sample available for cable database?
How to Preparation of online test
ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH