Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Questions :-
HR-
Q.1 about yourself & family background ?
Q.2 Why u choose Power sector as ur carrier starting not any
other sector ??
Q. 3 What think abt NTPC ?
Techincal Questions:-
Q.1 about Vocational Training……What u did , see the main
equipments….etc
Q.2 Why a transformer Noise during its running condition ?
Q.3 about transformer oil material & Test name for the
measurement of its dielectric strength & wht will u do if
its dielectric strength goes low ? ……..some discussion type ?
Q.4 What is relation between transmission lines &
Communication lines ?
Q.5 Which Machine u will prefer to use at a place where
flammable gases are coming out & why ?
Q.6 how fault in an electric system is detected & hw
protection of equipments is done ?
Q.7 Why we didn’t feel electric shock in an electric train ??
Q.8 Anything u want to ask from us ??

Answer Posted / jitender

I also need the answers.Pls send it at
jeet_lovemeet@yahoo.com
pls do it soon

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When color of silica gel will gets change from blue to pink from Top to bottom?

1549


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2081


single phase power supply give to separate one steel coup with water, what reaction create

2026


WHY L-G FAULT IS MORE SEVERE IN TERMS OF RRRV?

3137


i need mat lab program to find out the transmission line losses,regulation and losses

1854


What is meant by system?

1016


If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?

5149


what is doubling factor in making current of a breaker?

2011


how to identify vector group of three phase transformer by voltage method?

1562


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

2292


What is process of anneling transformer core

1915


how braking & making capacity of circuit breaker is calculated?

1961


Why transformer used in UPS??

1529


What is the equivalent circuit of a transformer and its vector diagram?

2641


what is the difference between the characteristics of two different phase bushing of any transformer

1768