Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why Power generation in India is at 50Hz while in America
its 60Hz so is there any advantage/Disadvantage of this ??

Answer Posted / raaju

Though it may be 60 or 50hzs, it never matter>>>>>enjoy the
power u get.........

Is This Answer Correct ?    2 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

oil cooled transformer

2280


if i am in front of transmission line how to know that current direction without any equipment

1839


Explain cmrr?

1182


can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you

2050


Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??

1754


Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault

2181


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1796


In our factory so many iron pillors are exists for supporting the shed/Hangar. If do more no of earthings at one piller instead of doing more earth pits in many locations and running earth strip around the hanger, I can save the money. Please suggest this method is acceptable as per Is specifications though the Earth resitance of the farthest piller is with in the limits as per IS specifications.

2177


why the frequency and voltage in india is 230v and 50HZ. when compared to USA say 110v and 60 HZ.

1509


How to know th details about an electrical Drawing ? Please mention the easy method.

2497


Is Transol transformer oil comparable to nynas nytro libra?

3165


what are the safety measures of induction motor?

2103


A cable with concentric PE conductor must be used with frequency converter circuits what does its means.?

1624


Is there a diode made that works with AC 120 volt 20 amp? If so can it completely stop all current flow in 1 direction at all times?

6795


Can we put 3 layers of cable tray while installing tray

2451