Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the role of reactive powerin transmission and
distribution?

Answer Posted / pushpak mistry

It is component of electrical power cause lower power
factor and drawing more current to give same output of
applications in terms of power.
Due to the higher reactive component in transmission and
distrubution, power loss become more in terms of
transmission line losses.
To reduce the transmit and distribution loss we have to
use higher size of conductor to transmt same power

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to know the Max. current caring capacity of the cable by its size ?

1651


would you please give me any idea about the BARC interview question on electrical? i have an interview on 1st july.....plz hlp me.......its urgent......

2466


How to calculate the Harmonics losses in terms of cost/unit.

2022


What is the instrument to check the rotating diode fuse of alternator in running conditions?

2472


What is the theoretical reason for the size of a zig zag grounding transformer to be 1.732 times less than that of a wye-delta grounding transformer used for the same application?

2272


what is thermal resistance of PVC Cable.

1801


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1862


What is the armature mmf in a D.C machine?

1239


plz send me the placement interview question and answers of whizchip(technical and apttitude)..i have an interview in next.

4985


What are the types of the glands and difference between single and double compression type of cable Glands.

2081


DIFFERENCE BETWEEN NORMAL TRAFO AND THRISTER TRAFO?

2610


How to calculate Voltage regulation of 22 KV Over head Line.

1661


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

2000


How is operate breaker failure scheme in substation

2117


Write down the design procedure of commutaj.

2133