Your B.tech marks is being given in CGPA grade. How is it
calculated?
Answer Posted / priyaranjan jena
first u add SGPA of both semister i.e (1st or 2nd,3rd or
4th) .And then divide by 2,which is the ans.or CGPA.
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
What is maximum power transfer theorem?
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
how hazordious area is classified at an oil & gas plant and categorise suitable class of electric equipment in that area like induction motors, LCS, Lighting Fixtures Fluerescent/Flood lights Mercury& sodium lights, J.Bs, Power Cables etc
if main CT is of ratio 50/5, and meter CT is -/5 what will be overall multiplying factor of meter.PT is 11000/110 .
When a square wave is applied to primary of a transformer then what will be output wave form of secondary ?
explain all the classes with example
sir i had plane to do some project with the base of hopkinson test in AC supply its possible
what is the minimum recommended leakage current of an earthed cable connected to the body or skid of an alternator
What is the role of Dedicated earthing in UPS System?
what is effect of leading power facter on the system and billing
State the factors, for the choice of electrical system for an aero turbine.
What are the types of the glands and difference between single and double compression type of cable Glands.
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
can u tell me the promotion from oiller to enginer
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?