I am looking for LV CT test. To check the polarity of the CT
only.
Can you suggest any supplier. Different companies are offering
CT/PT Tester which is expensive. Thanks
Answer Posted / gireesh
Omicron CT analyser is the best testing kit for CT.ITs is a
total CT testing kit, If you want to test only polarity, go
for Megger Make
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?
why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?
formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?
Explain about Leakage Test.
what is the difference between switch yard to residential area.and how much required it.
What is cut-off rate?
Brief working principle of stabilizer,application & safety precautions
how to calculate energy of 3-phase motor?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
Define norton equivalent circuit?
ht side line to earth voltage
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
how much leakage current is allowed in MC61A L&T make relay?
A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N
what is the purpose of bypass mode in energy lighting transformer?