I am looking for LV CT test. To check the polarity of the CT
only.
Can you suggest any supplier. Different companies are offering
CT/PT Tester which is expensive. Thanks

Answer Posted / gireesh

Omicron CT analyser is the best testing kit for CT.ITs is a
total CT testing kit, If you want to test only polarity, go
for Megger Make

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?

667


why the electrolyte level in lead acid battery is maintained 2.5 cms above electrodes?

1389


formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?

1637


Explain about Leakage Test.

1439


what is the difference between switch yard to residential area.and how much required it.

1259






What is cut-off rate?

753


Brief working principle of stabilizer,application & safety precautions

5146


how to calculate energy of 3-phase motor?

1542


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1347


Define norton equivalent circuit?

603


ht side line to earth voltage

1056


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

1549


how much leakage current is allowed in MC61A L&T make relay?

3116


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

2107


what is the purpose of bypass mode in energy lighting transformer?

2048