why our indian system choose the 230 volt for single
phase&415 for 3-phase voltage,in forign side 110 volt is
used what is the difference
Answer Posted / muhammad ashraf
In forign countries, they use 200V in three phae at 60 HZ
and according to the principal of electrical theory in star
connection phase voltages are under root 3 time less then
line voltages, and for domestic control we use star
connection, this the reason that in India and Pakistan we
use 415V three phase supply and according to the formula
single phase voltages will be 230, and according to this
standard our home appliances are design at 230 volts. And
forigner use 200V three phase supply And according to the
formula thier single phase voltages are 110V. And thier
design of home applinces are 110V.
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
Define closed loop control system.
HOW TO CALCULATE AMPs OF CURRENT TRANSFORMER IN HT Panel
why effective resistance should be more than static resistance in transmission line?
HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.
WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?
What are the disadvantages of autotransformer?
What is the basic principle of welding process?
Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
How can we increase fuel-power ratio of any DG set?
What is transient response?
I HAVE A 50A MCCB AS PER DESIGN LINE WIRE CONNECT UPWORD SIDE AND LOAD IS CONNECTED TO DOWNWARD SIDE TO THE MCCB.IF NOW ANY ONE CHANGE SUPPLY & LOAD(WISEVERSA) WHAT HAPPENS ? DOES MCCB OPERATION OR WORKING FUNCTION NORMAL IF YES THAN WHY THERE ARE MARKED LINE & LOAD ON MCCB.
What are PLC leader logic program method
Parts of machine and their discription in details with suitable photo
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.