when the rheostat kept in minimum to maximum position in
motors what will happen?
Answer Posted / ramanareddy
actually rheostat means -diverting......if keep the rheostat in minimum position motor will run at rated speed....if rheostat in maximum position ,the motor will run above the rated speed ,so that speed make the motor damage....
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.
why using transformer and thyristor switch in 3 phase apfc panel
i have total 8 dg sets for synchronizing and 2 buscoupler,1 sectoin dg no 1,2,3,and 2 sectoin dg no 4,5,6,and last section dg no 7,8 ....if buscupler no 1 and 2 is off mode ..than dg no 1,2,3,will synchroniz of another dg sets?
why does connected a indutor with mnsformeretering core of current transformer ?
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
what is the problem when i want to close a circuit breaker by local position it closes well.but when i close it in remote position it trips
How to calculate earth wire load by formula
plz tell me,ht and lt panel terminals in substations explain beiefly
What are the applications of autotransformers?
What is the significance of integral controller and derivative controller in a pid controller?
why the pf of semiconductor device is improved the electrical devices
whats the application of voltage regulation? and whats the voltage regulation's device?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?
Why should we hire you over the others waiting to be interview?