Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is mean by xlpe swa pvc

Answer Posted / lynx 3

xlpe: cross linked polyethylene
swa: steel wire armored
pvc: polyvinyl chloride

An xlpe swa pvc multi-core cable means that every core of
the cable is xlpe insulated, than the 3 or 4 cores together
are steel armored and pvc sheated

Is This Answer Correct ?    56 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the criterion for selecting vector group of Transformers ? i mean how to decide vector group of Generator transformer, substation trasformer and transformer at consumer end

2273


What is the settings of distance protection relay in 400 kv line

1608


Who are the manufactures those manufacturing 3Cx2.5sqmm FRLS cables. I heard about FRLS technology adopted only in wires useful for wirings

2022


how the B-H loop obtain under the static condition

2269


What is precision of a measurement?

1046


difine electrical ballast in HPSVL

2001


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1828


What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)

1516


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

2027


What is inverse definite minimum time lag relay? Where is it use?

2772


what is different between relay and plc?

5505


Approach of a cooling tower is the difference between temperatures of what factors?

1071


how to find Harmonics and types as per the equipemnts

1211


what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?

2031


what is the function of statics switch in ups and tell me parts

1972