Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why we use 25 kv in railway .not 11kv, or 33 kv

Answer Posted / senthil nathan

as per load requirement(TRACTION MOTOR, DC SERIES WOUND
MOTOR 782V, 250AMPS) They have selected this 25kv. because
using transformer power can not be varied voltage or
current may vary but power remains same.

Is This Answer Correct ?    9 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

the problem faced on star or delta winding connection??

1914


how you will decide the distance between the power transformer and its fencing

1958


Why do we apply both Differential and REF (HV and LV) protection schemes on YNyn configuration of a transformer?

2128


george phenomenon of synchronous machine

7540


In Power cable specification what is U0/U and Um.

3792


give single line diagram of D.G distribution form alternator to main L.T panel?

7557


What do you mean by per capita requirement of electrical energy in india

2238


how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me

1894


sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan

2205


State and define norton’s theorem?

1242


What is nichols chart?

1322


A 400 V, 50 Hz, Δ connected synchronous generator has a field reactance of 0.1 Ω and armature resistance of 0.015 Ω. At full load, the machine supplies 1200 A at 0.8 pf lagging. Under full-load conditions, the friction and windage losses are 40 KW and the core losses are 30 KW. What is the machine’s overall efficiency? Ignore any field circuit losses.

1901


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1519


Why do we need interlocking in a HT metering or Ring main unit switchgear?

2015


What is the exact minimum vale of voltage between an earth and netural which can damage or can do malfunction of the electronic equipments ? If this is mentioned in any book, pl.give reference.

2265