Answer Posted / kamalraj
Minimum reinforcement
The mild steel reinforcement in either direction in slabs
shall not be less than 0.15 percent of the total crosssectional
area. However, this value can be reduced to
0.12 percent when high strength deformed bars or
welded wire fabric are used.
Longitudinal reinforcement
The cross-sectional area of longitudinal
reinforcement, shall be not less than 0.8 percent
nor more than 6 percent of the gross crosssectional
area of the column.
NOTE - The use of 6 percent reinforcement may involve
practical diffkulties in placing and compacting of concrete;
hence lower percentage is recommended. Where bars from
the columns below have to be lapped with those in the
column under consideration, the percentage of steel shall
usually not exceed 4 percent.
| Is This Answer Correct ? | 100 Yes | 13 No |
Post New Answer View All Answers
what is conrete grade ,how are depent on concrete grad and size of concrete?
what are RIB slabs explain about it
In the design of bridge arguments what considerations should be made to select the orientation of the wing walls?
Detection of a beam & a girder are––––
What ingredients with% found in ppc cement??
How and where are aqueducts built?
in one hour , one 200 excavator , how much quantity (mcube)can load ? soil is not hard not soft
how to calculate the material from ratio of work PCC, RRM,POINTING, RCC
minimum number of bars in a beam? minimum and maximum column size and beam size ? minimum and maximum aggregate size used in multistorey residential building for columns,beams,slabs?
Can inverted beams used in pipes during construction? If yes, explain how it can be implemented?
What will you do if a portion of load bearing wall collapses under your supervision?
if in column reinforcement lower dia connect to higher dia then from wher we want to start higher dia steel
i just want to know how much require sand and cement for 1 sq.mt including wastage. Please guide me as soon as possible.
how much cement and sand consuptin in 4 inch siporex walls 100 sq ft
What are the phases inspections are done by local authority while construction?