Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the safety integrity levels (SIL)

Answer Posted / abu zarrar qaisi

Safety Integrity Level (SIL) is defined as a relative level
of risk-reduction provided by a safety function, or to
specify a target level of risk reduction. In simple terms,
SIL is a measurement of performance required for a Safety
Instrumented Function (SIF).

Is This Answer Correct ?    11 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1969


IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?

2283


How to Calibrate Coriolis Flow transmitter in field

1315


What is super thermocoupal?

2273


what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?

2522


What is the use of GMV in turbine?

4509


how to control pid

1969


Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?

1940


, Instrument Index, P&ID review, I/O schedule, datasheet, DCS / Analyzers specifications, loop diagrams, hook-up drawings.

8144


what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.

2149


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

2212


What materials are used in thermo wells?

1227


what deference between panel earth and systemearth

2379


HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with

2135


In apron feeder how TPH is calculated?

1789