What will the effect on a motor designed at 60 HZ, and
operated on 50 HZ ??
Answer Posted / nagaraju chikkala
If we operate like this, we can't get designed torque becoz v/hz ratio will be more than design v/hz ratio.
If we want to operate with 50 hz, we need to reduce the voltage as design v/hz ratio.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
describe the Operation of induction generators from bus bars
what do you mean by class PS CT and what are technical details needed for calculating it?
what are symmetrical and non symmetrical components in electrical installation.
In HVDC LINE RECTIFIER CONTROL ON CONSTANT CURRENT AND INVERTER CONTROL CONSTANT EXITATION ANGLE CONTROL BUT HOW INVERTER CONTROL CONSTANT CURRENT?
Dear sir, I have completed DECE in the year 1995. I have work experience in HT and LT LINE more than five years. Now i am doing BE in EEE from rajasthan university. After completion of BE,can i apply "C" Licence sir? Please reply.
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what exactly commisioning work does in electrical site work... LT side?..
Why line VTG = √3 phase VTG in star? How?
how can i get the formula to find out the cable size if i know the load of main fuse protection.
how many electricity poles are there and what are the names and their sizes.
how to calculate the size of the HT cable
Explain Circuit Breaker Trip Characteristics in detail.
An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?
what is the use of current transformer in power transformer secondary side.?its connectyed in WTI
What is the formula for selecting the cabels according to load? How to calculate what sq.mm cabel to be used?