what is the difference between auto tuning and manual tuning
of controllers(eg:PID,PI,PD CONTROLLERS )
Answer Posted / s.sasikumar
the above is correct. in auto tuning the parameters of
P,I,D values varies automatically with respect to feedback
values and it takes several hours to be in stable at
setpoint where in manual the operator has to give the P,I,D
values manually by taking the response in graph as per
zeigler-nichols method . And it consumes half of the time
to be in stable at the set point when compared to auto
tuning.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
any body please send me the old question papers of ongc test.
how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
How many ohms are required for proper earthing?
how many maximum enter 2mm Dia solid cylindrical pipe into 8mm Dia hollow cylindrical pipe. give answer with calculation.
please send the sample qustion paper for iocl written test ..
Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?
A length of steel pipe is used to carry sea water to a desalination plant. An adequate corrosion allowance must be specified and indicated in the piping specification, which affects the _________________________ of the pipe
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
why we use cascade control and feed forward control in 3 element drum level control measurement of steam drum .what is cascade and feed forward control system ?give example .
how to commission furnace ( water heater)
installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,
what is intrinscily safe system and where we use?
What is standard procedure of manual mapping in Radar type level transmitter?
What is the use of GMV in turbine?