Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY THE TRANSFORMER VALUE MEASURES IN KVA INSTEAD OF KW.

Answer Posted / jk

POWER GENERATOR AND POWER USER RATING IN KW
AND POWER TRANSMITTAL DEVICE IN KVA BCOZ THERE IS NO ROLL
OF PF

Is This Answer Correct ?    0 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why ct's&pt'S out put called as burden,why compelsary short ckt the secondary of ct's while removing the burden?

2160


what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated

1925


how to calculate the breaking capacity of different breakers.

2220


what is earthing.how we make it,describe briefly.

2558


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1739


If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?

1992


wht is embedded systems? what is new inthis field?

1949


how does directional relay work incase of ac ?

1446


Purpose of providing neutral isolation panel for parallel operation of diesel generator

1719


What is the difference between PS & metering CT (5p20,0.5 etc.)? Why in PS class CT only Vk is given ? Is PS class CT is more accurate than metering CT?

1063


what is the requirement regarding earthing of Single conductor with AWA

2168


What is the polarization index value ? (Pi value)and simple definition of polarization index ?

1140


what is the calculation method to design core and winding of a 200kva 3phase distribution transformer?

2344


What are the difference between CT/PT operated Meter and RRAMR Meter for HT/LT application?

2528


An impedance of 100 ohms resistance and an unknown inductance is connected across the capacitor. The resulting impedance is a pure resistance of 500 ohms ifω = 10^5 rad/sec. calculate the values of inductor and capacitor.

1354