Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to check maintenance free battery 12V,26AH using analog
multimeter

Answer Posted / k.prakashchandra

First charge the battery fully i.e. till charging current
becomes almost zero at 130% of rated voltage of the
battery.Then discharge till the terminal voltage becomes
90%.if AH (A xH ) discharge is more than 26 ,then the
battery is good.Do not allow charging or discharge current
exceed 5 A.

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is gas turbine intercooling ?

2038


3phase cable calculation formula by motor load

1464


If we impress a dc voltage of 230 V on an unloaded 230 V, 50 Hz transformer it wi A give high secondary voltage B burn out C give secondary voltage as per K D none of these

1956


why we permissive overreach in distance protection.where it is applicable to use in long r short lines

2702


What is the estimated total hydropower potential of india?

1087


Sir, I have applied for the of Jr.engineer(Electrical & Electronics) & ASST. LOCO PILOT at ALL RRB BOARDS. please send me all RRB Boards solved papers in the year of 2001 tO till date. i requested send me the papers to my id as soon as possible (jet_0991@yahoo.com). (This is very urgent) Thank You,

1784


What is the phase relationship between the primary and secondary voltages of a transformer?

1028


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1819


operation of diesel generator

1972


How equivalent impedance is calculated in thevenin theorem?

1076


what is the use of expulsition protective gap in 11Kv line.

2078


How can we calculate the motor frame sizes?

3366


Iin ESP why positive is grounded ? why not negative ?

2555


What is the lower limit of break-down voltage of converter transformer.

1858


mostly the questions were from machines... d.c. machines, transformer, synchronous and induction all theory paper........ few from power system... but the level of paper was easy.....