Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the use of breather in transformer?

Answer Posted / raul

breather is basically to absorb d moisture content in atmospheric air entering d transformer which can deteriorate d oil properties i.e. insulating properties n can cause acidity n sludge formation in the tranformer oil. so when ever the transformer oil cools there is a contraction of oil in d transformer tank which draws atmospheric air into the conservator through a breather which is a cylindrical tank containing silica gel crystals impregnated wid cobalt chloride which r initially blue in colour n when dey absorb d moisture d colour turns into pink. when 1/3rd of the crystals appears pink, flushing of the complete charge is done n fresh crystals r introduced into d breather............

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What Is Sampling?

1162


what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY

2147


While testing a ZCT what parameters have to check or measure?

2334


there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit

1873


how to select electrical equipment such as fuse,dg,transformer,motor,msb,wire,cable as per the connecting load..please mention any books to design,take licence

2936


for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?

1914


WHAT IS DIFFERENCE BETWEEN CAPACITOR AND CAPACITANCE?

1943


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The slip when motor stalls is A 1 B 0 C 13.33% D 10.33%

1850


i want to put single phase load on scott connected transformer,eventhough how to balance the transformer.

1783


Why mostly the HV side of transformer has Delta?

3160


Sir 33kva 2 transformer load 900 amp calc 1800 amp mana jayega

1778


How do we arrive at selecting reactive capacitance value as 30% of h.p rating of motor?

1784


if we apply 1000ADC instead of 100ADC or We apply 50ADC instead of 100ADC,What will be happened in the test result value.Pl explain

1250


why ht cable end termination don't have a gland?

2886


How Calculet The UPS AH In Load

1820