Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is principal to reduce earth leakage current with
isolation transformer? When isolation transformer is
installed in input stage of system, earth leakage current
is reduced. the reason is why the leakage current of 2nd
stage of isolation transformer does not affect the 1st
stage's leakage current. I would like to know the reason.
As you know, earth leakage current is a kind of AC. So, How
to reduce earth leakage current in case that isolation
transformer is used?

Answer Posted / k.prakashchandra

If the neutral of secondary is not earthed ,the phases of
secondary lose the reference to earth ,but slightly for
capacitive coupling. After the second stage ,the earth is
almost completely isolated.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

there are cam operated switches - why we call cam operated , What is cam ?

1894


Why the unit sizes of hydro generating machines are not standardized as in case of thermal powerplants?

1084


If I want to replace a 26KW Slip ring Motor with a Squirrel Cage motor & Drive (for a Hoist Application). How can I approximate the Motor & Drive HP required in new Setup.

2250


What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1855


The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.

1953


Q: How to calculate Transformer losses , tell us by Formula.

2049


I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.

2085


what is the difference between the characteristics of two different phase bushing of any transformer

1789


Can anybody post questions asked in Engineers India Limited Interview? Thanks in advance.

2365


kVA rating of ordinary transformer is increased when connected as an auto transformer because A transformation ratio increased B secondary voltage increased C energy is transferred both inductively and conductively D secondary current increased

2634


Give details of your interested designation, the post you are interested to serve the company better and explain why you think you can serve the company better in such position if employed?

3322


what are the safety measures of induction motor?

2033


what is the vvvf in the dumbwaiter?? or lift. what is the actual process?/

2072


What is the ideal position cooling fan inside the dc motor?

2072


If a surge divertor is required to be protected by 32 amp C Curve Circuit breaker does this limit the amount of protection from surges that you will acheive