If single phase voltage level is 230V than why three phase
voltage level is not 660V ?, but it is only 440V.
Answer Posted / s singh
In single phase case; 220 v is potential difference between phase and neutral, whereas in three phase case potential difference between any two phase terminals will be around 415 v. All three lines show a potential difference of aprox 220 v with respect to neutral but are but are apart from each other by an angle of 120 degree (phase difference) so will exhibit almost double potential difference between any two line terminals. So for all practical purposes potential difference between any two phase terminals will be around 415v. However for power calculations etc we multiply 415 with squareroot of 3 to get actual total line voltage which is a sine function of phase angle between them.
Is This Answer Correct ? | 53 Yes | 8 No |
Post New Answer View All Answers
What do you mean by screen of power cables?
what is the Transformer Impedence?How can calculate?
What is the unit of charge and current?
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
does the Trivector Meter of three phase automatically takes care of the low power factor and gives the reading accordigly or it does not take care of the Power factor while giving the readings please explain
how is control wiring coding is done in a CRP panel ?
what is level 2 automation?
how synchronous condenser is used in place of synchronous generator with out negotiating IEEE standards? Can i use 3 generators as synchronous generators and 2 generators as a synchronous condensers in an IEEE 14 bus system with out disturbing the standards?
If two Transformers are connected in parallel having impedance of 50KA in both transformers will the impedance increase or decrease after connecting transformers in parallel?
WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >
Brief working principle of stabilizer,application & safety precautions
can we synchronize star system generators with delta system generators?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
What is CCT (Correlated Color Temperature) ?
What is the Temperature to be set in Thermostat provided in Marshalling box of the Transformer / Motor.