What is cable size for intrenal wiring in DCS or PLC ,from
any card to Terminal amd Why

Answer Posted / chandra

internal panel wiring for DI,DO, AI, AO are usually 0.5,
0.75, 1.00 sq.mm depending upon the instrument, deivice
consumption.

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between modbus,fieldbus & profibus

1876


What is compensation for flow ? Why we use compensation ? What are the factors of different compensation ? We not use then what problems may happen ?

1477


why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??

6857


What is the PLC configuration in Cement industry?

3267


Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows

1646






I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1364


hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.

1690


where proximity sensor installed on tank in loading arm application

1782


what is effect of specific gravity in differential level transmitter , explain formula related with this .

1225


What is difference of fanuc alpha series 16i and 18i controller.also what is differnce betn TC and MC controller

1873


What is shielding effect?

1759


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

1631


why fuse block is not used for AI signal?

1396


Explain the difference between mmwc and mmwg?

3520


what is wave length were using ?

1478