Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is a Single Phase and Three phase Power? How it will be
converted or transformed into another form?

Answer Posted / pravin patil, amol, aher

Single phase means 230 V 50 Hz Power supply & 3 Phase means
415 V, 50Hz, For converting into another form like
mechanical or Heat Energy,Magnetic Energy.

Is This Answer Correct ?    3 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate fault level?

2259


How much voltage we need to apply in 33kv cable during hipot test of cable

833


Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)

1891


how tto ingress mw in turbine explain.procedure ?

2271


What do you understand by avr?

1021


WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.

2688


If we have 11 kv RYB Phase single core cable near about. Then wht effect and losses

1857


what is feeder bay?

1577


it is possible to rotate the DG engine dc starter with wrong polarity connections? why?

2233


what size steel armoured cable is required to support 1500kva capacity. would 70mm squared be enough or would I need 90 or 120mm squared 3c plus earth

1372


a)In a 3-phase 4-wire circuit, a circuit breaker is selected to protect the circuit whose highest fault level is 6.6 MVA. Determine the required minimum breaking capacity in kA. (Note: Covert 3-phase power in terms of kA to find answer.) b)Using the below, determine the required minimum making capacity in kA as a “peak value”. Rate breaking capacity (Icn) ka: Icn<= 1.5 Factor = 1.41 1.5

1692


what is transformor oil gread

2519


what could be the RMS value and average value of a 4 phase sine wave?

1865


What is BusBar integrity test and how it is conducted?

2227


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1883