in the flow caluclation k value how to caluclate.mass flow
& volum flow.
Answer Posted / mrmk
The correct term is K Factor.Normally this value can be
calculated in factory calibration and at field using meter
proving skids.
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
How many ohms are required for proper earthing?
what is function of sensor, and how is it work , explain with difination
If i have 4 Allen Bradely make RS logix 5000 PLC and for viewing that we are using 4 RS view SCADA for 4 different packages. Now, I will want to view two packages on only one SCADA. Then how i will do it?
How d.p. Transmitter can be applied to close tank?
How to Calibrate Temperature Switch in field
sir, i preparing hpcl,ongc,barc,hal exams(instrumentation engg)pls send a placement papers
Why is it necessary to use compensation leg to measure the liquid level in a closed or pressurized tank?
What are the key features of a Distributed Control System? describing the various layers (sensor through to business system interfaces) as well as the hardware, software and security aspects of the DCS.
WHAT ARE THE INSTRUMENTAL DIAGRAMSOF VALVES?
Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows
what are the documents(Construction point of view for a process plant) submitted by contactor initially entering in to new site for client?
WHAT IS TMXT IN TEMPERATURE FOUNDATION FIELDBUS.
Identification of control valve parts.
-/5A. What is the meaning and limitations of this in energy meter constant. It is a 3 phase LT Energy Meter. If this Energy Meter is connected through a CT of ratio 200/5 Amps, then what is the multiplying constant and how its will be calculated.