I want to give Power supply to a house from the Feeder,
Total Load of the House is 128 KW, how to calculate cable
size for this load ?
Answer Posted / s. patel
if you are using 1 phase with 128 kw then you need to select the 500 sq. mm or if you are using 3 ph. then you have to select 4x120 sq mm of copper pvc cable armored or unarmored
and fro alluminium 4Cx185 sq. mm pvc cable is require.....
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
What are the advantages and disadvantages of negative feed back?
I want to do a mini project. Now I'm studying in 6th semis tor EEE Engineering.
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
We have a couple of oil tanks at our plant. One of them does not have a lightning arrester installed. My question is it necessary to install an arrestor on every tank or will this particular one be covered by the arrestor installed on the ajdacent tank, Since all the tanks are close to each other. Basically, I want to know that if these arrestors or protection works in a parituclar area of effect or influence. Thanks
Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.
what is vA rating and class of a ct.
HOW DO I CALCULATE THE SETTINGS FOR THE DIFFERENTIAL PROTECTION OF A 12kV/6.6kV, 6MVA,DYN11 XMER WITH PRIMARY SIDE CTR 400/1 AND SEC SIDE CTR 600/1?
How many kw will suply from one db
what is gas turbine intercooling ?
What is the difference between a 3 winding and 2 winding Potential Transformer
Why single phase induction motors are not self starting ?
ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH
Define unilateral circuit?
my question is how to answer the question "you are from b.tech eee background and why do you want to go for banking
what kinds of Transformer oil grade is better for power transformer ?