how netral CT is selected (including its details
specification)
Answer Posted / n. basak
Mr. Manoj the following answer to point no. 7 may give you
some basic idea on type of CTs. Here I should mention that
I am not at all a CT expert:
The type of CTs mentioned are basic types of transformers
1. Wound type CTs a current transformer in which the
primary winding usually consist of more that one turn.Wound
primary transformers have an internal primary winding (in
CT mould)and have no windows for the primary conductor to
pass through. These are normally designed with low current
ratio, therefore are having higher accuracy & burden.
2. RING TYPE CTs : A CT which has an opening in the center
to accommodate a primary conductor which may be busbar or
cable through it. A current transformer where primary
winding is provided by user. They are cheaper.
3. Bar type transformer: The CT in which the primary
conductor is made up of a bar or a set of bars in parallel.
The bar is of suitable size (Copper or aluminium) and is an
integral part of CT.We can also define bar type CT’s are
window CT’s with a solid bar installed.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
technically, what is the reason behind starting the motor star the delta connection .. and what other ways to do this rather than using " star-delta transformer"
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
how give earthing conection to household equipment?
A 100KVA SINGLE PHASE TRANSFORMER 10000/200V,50HZ REQUIRES 300V AT HV SIDE TO CIRCULATE FULL LOAD CURRENT WITH LV SHORT CIRCUITED.THE INTAKE IS 1000W.THE % OF REGULATION ON FULL LOAD AT 0.8 PF LAGGING WILL BE HOW MUCH AND THE SECONDARY TERMINAL VOLTAGE ON 0.8 PF LEADING WILL BE
Why field rheostat is kept in minimum position while armature rheostat at maximum position?
current transformer balance the power level on both sides. e.g in case of step up, at secondary side voltage rise but current decrease and vice versa in case of step down transformer. but how this power level remains same in case of current transformer and voltage transformer
how to modify DOL control panel into Delta Y connection?
What is an Air COmpressor
How to check the thermocouple is correctly connected to cable for K type? (i,e positive pole is connected to non magnetic conductor and negative pole is connected to magnetic conductor)
Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA
Type of motor stater detail and working detail
What is the restart inhabit setting in ABB spam150c relay (Motor protection relay)
How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance