Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is mapping in instrumentation and control engineering

Answer Posted / fulbert

Mapping is either called I/O Mapping for configuring
Input/Output addresses between the devices in a control
system network.

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Can any one tell me what type of question asked for instrumentation and control interview panel??? pls mail ramashankar.goel@gmail.com

909


What care will you take in the installation of control valves,SCADA,DCS and FOC in Oil and Gas Project?

2132


please send the sample qustion paper for iocl written test ..

3716


How hart protocol can be connected with control valves?

1061


what are the selections available in configuring a burnout protection of a controller? thanks

1974


can anyone tell me about the basic concepts to consider before to start a PLC panel wiring

1947


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2782


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1404


In apron feeder how TPH is calculated?

1733


find the kp ki kd from the transper function G(S)=29.44s+04707/1.5349s2+s

1938


What is limitation of the ht.of the displacer of a level trol?

2400


what is o2 analyzer and how it measured ,what is the role of this analyzer in cfbc boiler...

2013


what is intrinscily safe system and where we use?

2527


what is interface level and how it is calibrate?

2403


what are the steps I have to deal with?

2247