Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the difference between MCB & MCCB,
Where it can be used,

Answer Posted / gaurav khanduja jaipurrrrrrr

MCB- MINIATURE CIRCUIT BREAKER
IT Trips the circuit in case of short circuit, over load
but not in earth leakage condition.
now in market mcb maxium rating is 100A

MCCB- Modular Case Circuit Breaker
It Trips the circuit In every Faulty Condition
Like- Short Circuit, Over Load, Earth Leakage Condition
it comes in the market From 40A

Is This Answer Correct ?    14 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why it is necessary to isolate fire fighting when you are taking shutdown for lv board.

1622


What is the minimum underground tank size capacity considered for firefighting purpose?

1941


How to calculate cable size in HT AND LT

1996


What is ignition module of a CAT Gas Genset G-3508 Engine, Alternator SR4B Series. HOw its checked for correct functioning.Is it repiarable or replacable?

2167


What are the basic component of a cro?

1225


What are the internal and external faults?

1084


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1524


What is transformation ratio what it describes?

1690


Draw a SLD of HT distribution EB grid up to users Transformer?

6197


What type of DC motor would you see for a lift?

1073


how is the cable tray designed & how its total length is calculated for an Industrial plant Say for Ex. (500KW Motor Load)

1883


A 100 kVA , 400 v/250 kv testing transformer has 8% leakage reactance and resistance on 100 KVA base . A cable has to be tested at 500 kv using the above transformer as a resonant transformer at 50 hz . if the charging current of the cable at 500 kv is 0.4 A find the series inductance required . Assume 2% resistance for the inductor to be used and the connecting leads . Neglect dielectric loss of hte cable . what will be the input voltage to the transformer ?

5249


which is better to use svc or synchronous condenser why ?

1803


What are the basic elements used for modeling mechanical rotational system?

1089


Difference between Lugs and Thimbles

15184