Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can we use 3 phase energy meter for measureing power in 2
phase 440 V phase circuit?

Answer Posted / k.prakashchandra

3 phase meter can measure the energy in the absence of one
phase.

Is This Answer Correct ?    3 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)

1912


what is the differation bewreen kwh & fundamental kwh in electronic trivector meters

2211


Is it possible to make a 5P10/ CT Ratio 50/1A Burden 5VA

1729


The moisture in air will condense at

1193


what is the formula for hv test for cable and circuit breaker..????

2050


what is per unit calculation?looking for simple and strong explanation thk u

2576


What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker

2021


diameter of cable and core is doubled then the value of capacitance is

4313


HOW TO DESIGN THE body EARTH cable(Copper Conductor) size for 60KVA UPS?

2005


For high frequency application we use which transformer?

1943


how do i commission a distribution transformer knowing all its ratings and transformation ratios?d

4599


please send me the L&T Emb. sys. placement papers and entire details of pattren

2337


What is mean by Sensitive Earth fault & what are the effects

4541


If oil and air can withstand a high MeV when used as an insulator in a transformer, what are the values of how high for each material?

1898


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero