1.what is the difference between MPCB and MCB ?
2.what is the difference between MPCB and MCCB ?
Answer Posted / chetan
MPCB-MOTOR PROTECTION CIRCUIT BREAKER
MCB-MINIATURE CIRCUIT BREAKER
MPCB TOTALY DIFFERENT FROM MCB AS IT IS NOT ONLY SIMPLE
CIRCUIT BREAKER AS MCB IT HAS INBUILT OVERLOAD RELAY RANGE
IF THE LOAD ON THE MOTOR EXCEEDS ITS CURRENT ABOVE THE
LIMIT OF MPCB IT TRIPS.
MCCB-MOULDED CAGE CIRCUIT BREAKER
MCCB IS A CIRCUIT BREAKER HAVING HAIGH LOAD CAPACITY THAT
IS ABOVE 63 AMPERE WE ARE GENERALY USE MCCB INSTED OF MCB
| Is This Answer Correct ? | 15 Yes | 7 No |
Post New Answer View All Answers
Is it possible to protect 3phase overload and earth fault of the 3phase system using two CT's.
Q) Write VBscript code along with QTPscript code in QTP tool for below scenario 1. Launch yahoo site(i know) 2. Do loogin(i know) 3.Click inbox link(i know) 4.Go to every page of mail box and count no.of read mails and no.of unread mails(i know) 5.Store page numbers, read mail count and unread mail count in a new excel file sheet 6.Create 10 types of graphs on that data 7.Do logout and close site(i know) 8.Save new excel files with graph
How to work meggar?
What is the normal phase difference between the voltage and the no-load current in a transformer?
why swityard is necessrry requirement in any bis power distributin systems?
what is the main difference between power devices and signal devices
What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?
As a electrical engineer.. what are the basic norms should follow in transformer oil testing.. 1.What is the Electrode type? 2.How long time you will give for oil testing?
i have gear oil pump with single phase motor.some time its motor starts running in reverse direction rather than forward direction...whats the reason behind this issue. 1- either capacitor is week? 2- or winding is week?
Single line diagram for dbb (double bus bar)system.
What are the parts in a inverter?
There are different classes of protections in power plants.class a,b,c are clear..is there any class d and e r there..and elaborate class b protection.
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
What is milivolt dop test in Busducts? What is its significance & procedure to do the test?
pls,send the previous year written test questions.