what type of oil is used in transformers? a)conduting b)
insulating
Answer Posted / jayesh pillai
oil used in transformer must be for
insulating
cooling
having high dielectric strength
bdv must be higher than 45kv
low viscosity oil
| Is This Answer Correct ? | 5 Yes | 3 No |
Post New Answer View All Answers
In siemens PLC, why do we want to move the data ?
What is the difference between shortcircuit current, rated current of cable & MCB with example? What will be the size of cable required for 5.5 KW motor (Full load current 10 Amps approx.), Starting current with DOL is 120 Amps. Aprrox. Short circuit current with LLLG fault is 2000 Amps Approx.
what do w do when the output of generator is fluctuating?
We have two parts in generator, electrical & mechanical. how it works?
What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
mostly the questions were from machines... d.c. machines, transformer, synchronous and induction all theory paper........ few from power system... but the level of paper was easy.....
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformerÂ
In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?
Difference between drift current and diffusion current?
1.What will be stored in online ups EPROM IC?
why three phase capacitor takes unbalanced current in capacitor bank?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
how to carry out Magnetizing Current Test on Distribution transformer and what purpose we are doing this test. why transformer rating in always in KVA ? what ispositive, negative, zero sequence impedence? How ElCB tripping if Neutral touch with ground Why AC & DC capacitor are use in UPS ? why motor rating in KW? how to syncronize two dg sets
Define phase lag and phase lead?