what is cogging and crawling
Answer Posted / shweta gupta
When the voltage is low, the rotor of Squirrel-Cage motor
refuses to start at all. This happens when the number of
stator teeth S1 is equal to the number of rotor teeth S2
and is due to the magnetic locking between the stator and
rotor teeth.This is why this phenomenon also known as teeth-
locking or cogging.
The Squirrel- Cage type motor sometimes exhibit a tendency
to run stably at speeds as low as one-seventh of their
synchoronous speed Ns. This phenomenon is known as Crawling.
Is This Answer Correct ? | 19 Yes | 5 No |
Post New Answer View All Answers
diff.between servo motor and ac motor
Name the component u would expect to find in a switchgear assembly?
ow can i get certificate of competency as electrical supervisor and my diploma in electrical engineering from jalgaon.
what is the efficiency of thyristor
15hp motor wound by 0.9mm & 0.95mm magnet wire. at no load test it draw 4.2A current. Another motor with same condition draw 9.2A current. How can that occur? pls help
How to calculate Air conditioning capacity for a telecom BTS shelter?
Ac generato how produce power I need for camplet defination
how indusrial diesel generator work
WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?
What is the HVDC Transmission System? What are the conditions applicable to lay an HVDC Line?
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<
how the B-H loop obtain under the static condition
Why should we hire you over the others waiting to be interview?
What is the difference between indoor and outdoor transformer
importance of reactive power management