What is the basic difference among IPS,UPS,EPS?
Answer Posted / qureshi majid
Ips-
Integrated power supply: used for integrated power consumption.
Ups-
Uninterruptible power supply:Battery used in the event of
power outage
Eps-
Electric power supply
| Is This Answer Correct ? | 26 Yes | 18 No |
Post New Answer View All Answers
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me.......
how to calculate the fault in substation
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
what is the effect of power factor of machines in starting current
How select ELCB for 32amp. socket having quantity 12Nos. We have to do this wiring in PLANT. Please Also explain the incoming cable specification.
which book to refer in electrical engineering for iocl exam & which book for general english.
it is possible to rotate the DG engine dc starter with wrong polarity connections? why?
WHAT DO YOU MEAN THE DIFFERENT TYPE OF CURVES OF RELAY LIKE STANDARD INVERSE, VARY INVERSE, NORMAL INVERSE, LONG INVERSE ETC....
Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.
in 6.6 kv vaccum circuit breaker vaccum bottole vaccum capacity ????
what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????
What is the minimum underground tank size capacity considered for firefighting purpose?
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
What type of DC motor would you see for a lift?
Why we make earth connection with Transformer Body and What will be the minimum size of copper wire as per code with respect to KVA rating of Transformer?