Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the Difference Between MCCB & ACB & VCB

Answer Posted / pankaj kr. gupta

MCCB is MOLDED CASE CIRCUIT BREAKER
ACB is AIR CIRCUIT BREAKER
VCB is VACCUM CIRCUIT BREAKER

VCB is MORE PROTECTIVE IN COMPERSION TO ACB
THEREFORE WE USE VCB IN HT SYSTEM FOR MORE PROTECTION.

Is This Answer Correct ?    0 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can i use REF and diffrencial relay both in 1 CT core for transformer protection?

1921


How shall i select the value of capacitor or inductor in a system?

1953


True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)

1663


Please brief me about number of pole in alternator.In single phase alternator coils are connected in star or series. How to calculate frequency for the same.

1972


Explain the working of variable frequency transformer?

1217


why Y CONNECTION IS BETTER INTERMS OF EFFICIENCY AND P.F FOR A LAOD LESS THAN 40% AND WHY AFTER DELTA IS BETTER FOR > 40%

2008


hi , i have 150 kw loud and we need 50 m cabil,i want to know wich size cabil we use. thanks

2207


what is the path of thunderlightening? once both a buffalo and a person were standing 5m apart but lightening hit and killed buffalo not person?

2919


Hi, My plant daily consumption is calculated as 3.8MWH but my supplier has sanctioned an power of 2.6MW per day. how can i equal or distinguish this two factors

1954


given data are load current & power factor cable core size? plz any one update the calculation formula

1939


Difference between drift current and diffusion current?

1939


what is the difference between elcb and rccb ?

2430


Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used

2695


how we can calculate power factor in single phase & three phase ?thank u

2051


if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit

1923