In a synchronous motor armature current flows due to
revolving flux which in turn rotates the load,but in no
load condition armature current is zero hence thr is no
revolving flux then how motor rotates?
Answer Posted / rakesh
This is funny , how on earth could u assume that the no
load condition of a motor means open circuit condition ,
now listen the 3 phase supply given to stator produces a
rotating magnetic flux which reacts wit the initially at
rest field conductors to set up an induced emf lagging the
flux by 90* , but the field mmf set up leads the stator mmf
and rotates in the same direction as the rotating field (
note that i m already considering that the motor has
starting mechanism i.e. damper winding and later on dc
excitation ) thus the two rotating mmfs are stationary wrt
to each other but rotating at synchronous speed wrt
stator , since the rotor mmf i.e field mmf has the tendency
to follow the resultant air gap mmf so electromagnetic
torque acts that sets the rotor rotating . it must be noted
that the field mmf is proportional to field current while
the armature mmf is prprtnl to armtr crrnt , hence at no
load the armature mmf is maxm, because the arm current is
maxm, while with increase in load the current decreases and
hence the arm mmf , however the reasultant air gap mmf
always remain constant till voltage supply and the
frequemncy are maintained constant, it is only that the
field mmfs and the armature mmfs change in orientation and
magnitude.
| Is This Answer Correct ? | 0 Yes | 1 No |
Post New Answer View All Answers
What are the types of transformers according to the arrangement of iron cores?
what is servo motor & how does it work.
66kv under ground cable how to layaing in ground any special case two ckt r runing
1.4 What is meant by CT knee point voltage and how would you determine it
WHICH SIZE A.B.CABLE IS USED FOR 11KV.
what is the use of permanent magnet generator in exciter
11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter
IN dc capacitive reactance is??
Scott connection is used for A 3-phase to 2-phase conversion B to achieve higher effciency C to save copper D to reduce harmonics
In a single how much maximum current and watts using
tan delta equation test on alternators
can you any one give exact mathematical relation between AC current and DC current?
Why phase sequence must be same in any ht motor or generator circuit?if phase sequence doesn't same whatever will be affect on circuit?
can u give me a brief idea about power line carrier communication ??
please send the last 5 years {{{JUNIOR ENGINEER - ELECTICAL, ELECTRONICS RRB CHENNAI and secundrabad}}} TECHNICAL question papers TO MY EMAIL ID dinesh100701@gmail.com