Why does the power consumed is always constant even if a fan
speed is altered?

Answer Posted / rakesh

it must be clearly mentioned here that a fan always uses a
single phase capacitor run induction motor , where there
are two windings to provide the two phae supply to generate
the revolving magnetic field , the torque developed is
proportional to the prdct of starting current , main
current and the sine of the angle btwn them , nw whe we
increase the resistance betwn the main wndng and voltage
supply , the voltage remainds the same while the current
decreases , the electrical equivalent of the mech power
developed i.e eicos# decreases , thus power dusnt remain
constant

Is This Answer Correct ?    4 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

i need previous entrence exam papers of nhpc.

2355


can any one provide me a connection wiring diagram for a DG set control panel along with BOM?

1751


draw a circuit diagram connecting transformer OLTC- RTCC- VCB-Marshalling Box otherwise Explain in words

22123


Why AC current leads voltage in capacitor and how?

1608


what transformer we used normally and upto which kva?

1486






What is the one main difference between ups & inverter ? And electrical engineering & electronics engineering ?

654


what is the function and use of cable differential protection relay?

2392


how to differentiate a mpcb,mcb with a contactor? Explain their working operation

1648


Does magnetomonopoles exists? one maxwell equation strongly suggests no, but how about their existance in plasma?

1470


How maesure earth neutral value & how much maximum value value required in between earth & neutral.

1583


How much ph is maintained of water resistance starter for slipring induction motor ?

1970


EHV current carrying parts need to have smooth finish,then how can a 245kv GIS with emery finish can run so long?

1388


1)How much current can a 3-1/2 core 100 mm wire carry? 2)What are the special cables required for explosion proof wiring? 3)In case you do not have coal and salt for earthing, how can you achieve good temporary earthing? 4)One horse power single phase motor is more likely to get hot than a one horse power 3 phase motor. Is it true or false, if true why? 5)What are the different types of soft starters for large motors?please explain?

4218


Dear Brother can u tell the proper size selection of cable & the fault level calculation of braker, busbar etc. pls mail me at azeemk30@gmail.com

1427


Y phase plates are used in transmission line??? what is there need???

2431