what will happen when a electric bulb is connected between
two phases.it will glow or not
Answer Posted / partha deb
Answer written by Ramendra Shukla is perfect.
if a 220 V bulb is connected accross 415 V then the blub
will glow much higher then usual but for the time being as
high potential will burn out the fillament wire of the bulb.
And for those who is telling that it require a return
path - tell me then how a motor operates at 3 phase?where
is the return path?
There is no return path required in 3 phase or 2 phase as
in 3 phase syestem each phases wire act as the return
path;the basic concept of how electrons flow in three phase
system thereby Current.
| Is This Answer Correct ? | 30 Yes | 2 No |
Post New Answer View All Answers
Can any body tell me about INNER SHUNT COMPOUND MOTOR diagram?
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
how choose conductor&depending upon load
Dear Respected sir how to test ABB REX521 protection relay by relay tester.
When lag/lead/lag-lead compensation is employed?
What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?
can anybody send the rrb chennai &rrb bopal question papers of 2006&2007.My exam is on 12 oct 2008.Its urgent
WHAT IS AIR GAP VALUE IN MM FOR A 11KV BUSHING OF 11KV/440V DISTRIBUTION TRANSFORMER. AND AIR GAP VALUE OF 25 KV BUSHING OF AT TRANSFORMER OF 25 KV TRACTION. WHAT IS THE CALCULATION FOR THE AIR GAP PERMITTED FOR BUSHINGS AT DIFFERENT VOLTAGES.
Explain what is clipper and clamper circuits?
A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
Which motor connection is preferable star-delta or delta-star?
any idea abt REVERSE METERING concept.........?
Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?
what are the advantages disadvantages of connecting high voltage block( 1:1 transformers) transformers between the turbo generators and busbars.
What's the difference between non break power supply and non break non short break power supply