Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How much voltage we get between two wire of 4 to 20 ma
output? Is this voltage up or down respectvice to 4 - 20
ma ?

Answer Posted / sathish kumar

It depends on the resistor. For 4-20mA o/p 200ohm resistor
wants to use. For 4mA o/p is 0.8V and 20mA o/p is 4V. It it
exceeds 4.4V means it will be short cicuit. To avoid these
problem zener diode will be use across the resistor for to
protect the system.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define the difference between a stable versus an unstable controlled system and some of the tools you might use to be able to detect when this is happening and assumptions used for control system application design that could contribute to instability

1883


Whatis the reset ofset and control system in instrumentation

2120


types of cable..? Use of every types of cable..?

2186


Make a ladder diagram on LSL valve will close, on PSL valve will open and start the motor

2190


How to calibrate Toxic gas detector?

1765


How to calibrate an pressure gauge with yantrika test bench?

2945


How can you add value to this Industry if offered the job?

1648


how u calibrate pneumatic n motorized c/v?

2009


pls provide me syllabus and old question paper of instrumentation engineering for GET(JSPL)

2323


give eg of how I/P is used in control loops

1995


define feed forward control loop with example and drawing?

3249


any body who gone thru recent iocl interview.INSTRUMENTATION questions. I need.

2538


What are the application of bernoulli’s theorem?

1197


Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =

1984


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

1946