Answer Posted / k.prakashchandra
The gap between towers depends upon ground clearance and the
conductor.The sectional clearance between conductors is
minimum 3.5 m
| Is This Answer Correct ? | 3 Yes | 1 No |
Post New Answer View All Answers
pls someone send me sample question papers along with the key.thanks in advance
What is steady state response?
how we can calculate 2 phase welding transformer rating or total power?
What is the range of the stator resistance of 3 phase induction motor?
how a resistor resists to flow the current?how an inductor oppses the sudden change in current?how a capacitor opposes a DC voltage.
What is “pu” in electrical engineering?
I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?
what type questions asked in hp cl
Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.
how to electrically make connection to ferroli GN2N?
What is given by the definition in BIL IMP/PF = 950/395 kV. This was found in a name plate of a power transformer.
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
Can any body tell gulf interview question for experienced electrical engineer ?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
how to modify DOL control panel into Delta Y connection?