Answer Posted / guruvendrakumar
potential difference between the two ends.It is called voltage.
flow of free electrons,It is called current
| Is This Answer Correct ? | 24 Yes | 8 No |
Post New Answer View All Answers
why all the feeders are designed in a particular manner ... is there any reason for that???
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.
what are the advantages and disadvantages of speed control of 3 phase induction motor by varying frequency explain with drawing
What is the general power factor & min. power rating of TV,LCD type TV, CRt type TV, Scanner, printer?
what is the calculation formula for motor starting torque,running torque, running torque.
please send previous exams question papers
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
Write masons gain formula.
Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.
how to determine ct ratio in ht vcb?
how we can calculate power factor in single phase & three phase ?thank u
Why 1/3 is used in symmetrical components?
for a 500 KVA connected load, I calculated 30% of capactor for power correction. Even after using 225 KVR capactor PF is not improving. What could be reason for low Phase correction factor?
Damping resistor provided in open delta (tartiary) winding of a measuring PT at the incoming of a MV inverter drive panel is getting heated up. Can any body explain the reasons and suggest the remedy?