How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
What is the Working principle of Dozing valve?
please any body have most important data for study for saudi aramco test of instrument QC thanks email shahnaveedullah@gmail.com
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
1. what is modbus cable? 2. what kind of communication we are using for the interface of DCS, ESD and Third party cabinets? 3. What is serial communication and peer to peer communication?
How to change dcs card in online. (Dsc is maxdna)
How to Calibrate Ultrasonic flow Transmitter in Field
how u calibrate sox nox co2 co in cemps?what is opacity n HPm?tell the standard parameters of cems?
I want measure the volumetric flow of gas in waste heat recovery Boiler?Tell me how and which type of instruments required. Plz mail me:naba02222@gmail.com Sam please post the answer .
How oil line flow measured?eplain about instruments used and working principle?
Why upper weighing limit of electronics balance is 90% of the total weighing capacity?
If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?
can any one tell me when ongc placement test and its forms is available????/ pls tell me if u know
In control valve proximity inductive sensor is taken as digital feedback for full open and full close.Normally its volts 24v when the sensor acts the feed back voltage 14v so that our relay not indicating in plc panel . kindly give the solution.