sir please send me previous year questions of jspl through
which i could prepare myself fpr the test.
Answer Posted / chandan gupta
hii... Can u pls send me the syllabus/quesiton pattern for
JSPL - GET on mechanical engineering section..... plss sir.
my id is chand_gupt@yahoo.com
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Dear all i am kumaravel. now in chennai. my work is control and relay panel auto cad designing.up to 11kv to 400kv then question is i am improving my knowledge. i want some books name and auther are available for this C&R panel related. plese any one help me
Why do we apply both Differential and REF (HV and LV) protection schemes on YNyn configuration of a transformer?
Mention the disadvantages of low power factor?
PLZ EXPLIN ABOUT CLASS PS CLASS CT .WHY THEY R DESINED AND FOR WHAT PURPOSE?WHY OTHER CT CANT BE USED AS PS CLASS CT? EXPLAIN IN SIMPLE LAUNGAGE IF POSSIBLE PLZ GIVE CIRCIT DIAGRAM?EMAIL-RAJ_SINGH_0376@SIFY.COM
DRAW ACIRCUIT DIAGRAM OF 100 KVA 415V/55-0-55V DELTA TO STAR TRANSFORMER
i wasted one year for the job after completed my btech what can i say about 1year time in interview
how to get electrical supervisor competency certificate in gujarat. i did 3 year diploma in electrical
What is the Designing & Selection Procedure for a DG/Transormer of rated capacity?
what the function breaker failure scheme, how is it operated
How many turns are there in primary winding? (In Transformer)
why we have to particulary use ACB for below ratings,even available of MCB,MCCB with that range ?
why and where we use early make & late break contacts in protection?
How we can recongnise the phase displacement of transformer connection between primary & scondary...plzzz explain it with example.........
Ratings of power transformer,Distribution transformer.
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?